Independent water analysis · LondonFilter performance report
Filter Performance Analysis — Domestic Water Jug Filter
A paired influent and effluent analysis of a standard activated-carbon jug filter, challenged with the same Westminster mains water characterised in our tap water report.
- Report number
- EL-2026-04829
- Date sampled
- 04 August 2026, 09:05
- Date received
- 04 August 2026, 13:20
- Date issued
- 18 August 2026
- Product tested
- Domestic gravity jug filter, activated carbon and ion exchange cartridge
- Cartridge state
- New cartridge, conditioned per manufacturer instructions
- Challenge water
- Westminster, London SW1 mains supply (as report EL-2026-04817)
- Throughput at sampling
- 40 L (approximately 25% of stated cartridge life)
- Protocol
- Paired influent/effluent, triplicate filtration, mean reported
- Temperature on receipt
- 5.1 °C
Summary
The cartridge substantially reduced chlorine, chlorination by-products and lead, partially reduced PFAS and microplastics, and had limited effect on nitrate, fluoride and dissolved salts.
The same mains water characterised in report EL-2026-04817 was used as the challenge water, so influent values are directly comparable between the two reports. Free chlorine was reduced by 94.7% and total trihalomethanes by 80.6%, which is the expected behaviour of an activated-carbon medium and accounts for the change in taste and odour users report. Lead fell by 84.2% and copper by 79.0%, consistent with the ion-exchange component. PFAS reduction was partial: the sum of twenty compounds fell by 41.9%, with better performance on long-chain compounds such as PFOS and PFOA than on short-chain compounds such as PFBS. Microplastic particles were reduced by 78.6%. Nitrate, fluoride, sulphate and chloride were essentially unchanged, and hardness fell by 21.9% — enough to slow scale formation but not to soften the water. Microbiological indicators were absent in both influent and effluent; a carbon filter is not a disinfection device and colony counts at 22 °C rose slightly, which is normal for carbon media.
- Free chlorine reduced 94.7%; total THMs reduced 80.6%
- Lead reduced 84.2%; copper reduced 79.0%
- PFAS sum reduced 41.9% — long-chain compounds outperform short-chain
- Microplastics reduced 78.6% (1.4 → 0.3 particles/L)
- Nitrate, fluoride, sulphate and chloride essentially unchanged
- Hardness reduced 21.9%; not a disinfection device — colony count rose slightly
Chlorine
94.7%
Free chlorine reduction
THMs
80.6%
Total trihalomethane reduction
Lead
84.2%
Reduction from 1.9 µg/L
PFAS sum
41.9%
Partial reduction of 20-compound sum