London Water Testing logoLondon Water Testing

Reporting

Sample reports

Every parameter we test, reported the way we report it. Two complete examples — a full drinking water analysis and a paired filter performance analysis — laid out on A4 exactly as issued, with analysis performed by accredited specialist partner laboratories.

Drinking water

Full Drinking Water Analysis — Westminster, London

A complete as-supplied analysis of mains drinking water from a central London property, covering every parameter group in our testing catalogue.

Determinations
68

Individual parameters reported

Exceedances
0

Against applied reference values

PFAS sum
10.5

ng/L of a 100 ng/L guideline

Hardness
278

mg/L CaCO₃ — classified hard

Summary

The sample met every statutory and guideline reference value applied in this report. Hardness is high, chlorination by-products and trace PFAS were measurable but well below guideline values.

  • 68 determinations; no result above an applied statutory or guideline value
  • E. coli, coliforms and enterococci all absent in 100 mL
  • PFAS sum of 20 compounds: 10.5 ng/L against a 100 ng/L guideline
  • Total THMs 31 µg/L against a 100 µg/L limit
  • Lead 1.9 µg/L against a 10 µg/L limit — plumbing-derived, first-draw dependent
  • Hardness 278 mg/L CaCO₃ (hard); microplastics detected at 1.4 particles/L
View sample reportEL-2026-04817 · Sample report

Filter performance

Filter Performance Analysis — Domestic Water Jug Filter

A paired influent and effluent analysis of a standard activated-carbon jug filter, challenged with the same Westminster mains water characterised in our tap water report.

Chlorine
94.7%

Free chlorine reduction

THMs
80.6%

Total trihalomethane reduction

Lead
84.2%

Reduction from 1.9 µg/L

PFAS sum
41.9%

Partial reduction of 20-compound sum

Summary

The cartridge substantially reduced chlorine, chlorination by-products and lead, partially reduced PFAS and microplastics, and had limited effect on nitrate, fluoride and dissolved salts.

  • Free chlorine reduced 94.7%; total THMs reduced 80.6%
  • Lead reduced 84.2%; copper reduced 79.0%
  • PFAS sum reduced 41.9% — long-chain compounds outperform short-chain
  • Microplastics reduced 78.6% (1.4 → 0.3 particles/L)
  • Nitrate, fluoride, sulphate and chloride essentially unchanged
  • Hardness reduced 21.9%; not a disinfection device — colony count rose slightly
View sample reportEL-2026-04829 · Sample report

What every report contains

Sample details

Where, when and how the sample was taken, and the condition it arrived in.

Plain-language summary

What the results mean, before any table is read.

Full result tables

Every parameter with unit, result, detection limit, reference value and method.

Reduction data

For filter reports, paired influent and effluent results with percentage reduction.

Technical observations

Context on why a result reads the way it does.

Scope statement

What the report does and does not say.

Browse every parameter